SWITCHABLE FILTER BANKS

MODEL AFS-12WB

 

afs-12a.JPG (18226 bytes)

Models AFS-12WB contain banks of Matrix Model FLT-1 filters. Each filter may be individually selected. 

The Model AFS-12WB retains the manual operation in addition to remote control through the GPIB IEEE-488 interface. Optional internal Post Amplifier PA-20-20 with a gain of 0, 17 and 32dB @ +5dBm max..

 

For filter specifications for the standard and wide band (WB) filters, see Model FLT-1.

Picture of AFS-12 filter selector with external connections

MODEL AFS-12WB SPECIFICATIONS

Manual Controls: Filters are selected using a keypad.
Primary Power: 110-120 Volts, 50-60 Hz. Other voltages and frequencies available.
Remote Controls: Filter selection through the GPIB IEEE-488 bus interface.                                

MODEL FLT-1

The Model FLT-1 is a discrete, narrow, bandpass filter. It is available in both standard and custom configurations. Typically, the Model FLT-1 is used at the input of a spectrum analyzer to eliminate the possibility of distortions created by spectrum analyzer.

Standard filters pass a single channel's on-frequency distortion. Wide filters pass the video carrier and the Composite Second Order Beat distortion products +/- 1.25 MHz of the carrier. 

Call for custom applications.

SPECIFICATIONS

Frequencies Any frequency from 5 to 1500 MHz.
Standard Filter:
Rejection:
Bandwidth:

At least 50 dB down at +/- 6 MHz from center.
+/- 1.25 MHz at 3 dB points.
Wide Filter:
Rejection:
Bandwidth:

At least 25 dB down at +/- 6 MHz from center frequency. +/- 1.25Mhz @ +/- 0.2 dB ripple.
Input Impedance to connector type:             50 Ohm BNC, N or SMA. or  75 Ohm (optional) F, BNC, or N.       NOTE: Input and Output Impedance to connector type maybe different.

 