The Model FLT-1 is a discrete, narrow, bandpass filter. It is available in both standard and custom configurations. Typically, the Model FLT-1 is used in conjunction with a spectrum analyzer to eliminate distortions created in the spectrum analyzer when multi-carrier distortions are to be measured.
Standard filters pass a single channel's on-frequency distortion. Wide filters pass the video carrier and the Composite Second Order Beat distortion products on both sides of the carrier.
Call for custom applications.

SPECIFICATIONS
| Frequencies | Any frequency from 5 to 1500 MHz. |
| Standard Filter: Rejection: Bandwidth: Insertion Loss: (single filter) |
At least 50 dB down at +/- 6 MHz from center. +/- 1.25 MHz at 3 dB points. 3.0 to 7.5 dB (depending on frequency). |
| Wide Filter: Rejection: Bandwidth: Connectors: |
At least 25 dB down at +/- 6 MHz from center frequency. +/- 1.25Mhz @ +/- 0.2 dB ripple. SMA. |
| Options: Input Impedance: Connectors: |
75 Ohm ( 50 Ohm optional ). |