MODEL FLT-1

The Model FLT-1 is a discrete, narrow, bandpass filter. It is available in both standard and custom configurations. Typically, the Model FLT-1 is used in conjunction with a spectrum analyzer to eliminate distortions created in the spectrum analyzer when multi-carrier distortions are to be measured.

Standard filters pass a single channel's on-frequency distortion. Wide filters pass the video carrier and the Composite Second Order Beat distortion products on both sides of the carrier. 

Call for custom applications.

Picture of filter components

SPECIFICATIONS

Frequencies Any frequency from 5 to 1500 MHz.
Standard Filter:
Rejection:
Bandwidth:
Insertion Loss:
(single filter)                           

At least 50 dB down at +/- 6 MHz from center.
+/- 1.25 MHz at 3 dB points.
3.0 to 7.5 dB (depending on frequency).
Wide Filter:
Rejection:
Bandwidth:
Connectors:

At least 25 dB down at +/- 6 MHz from center frequency. +/- 1.25Mhz @ +/- 0.2 dB ripple.
SMA.
Options:

Input Impedance:                                  Connectors:

75 Ohm ( 50 Ohm optional ).

 